No. 174 Ermin Garcia St. Brgy. E. Rodriguez Sr., Cubao, Quezon City. Philippines. 1109

8912-2713 | 8912-4213 | 09276060091 | 09177069448

Industrial Fans and Blowers
CENTRIFUGAL FANS & BLOWERS
PROPELLER FANS & BLOWERS

TFB-01
SIZES
SISW Scroll Type
Tork SISW Scroll Type Fan is designed for a wide variety of applications from commercial ventilation to industrial ventilation systems. Known for high efficiency, low sound levels, and low horsepower, this fan is used extensively in supply and exhaust systems.
12" - 73"
MAX CFM
147,000
MAX W.G.
14"

TFB-02
SIZES
DIDW Scroll Type
Tork DIDW Scroll Type Fan is designed for greater volumes to suit industrial supply and exhaust systems as well as HVAC applications and variable air volume systems. This fan has a wide variety of accessories to match each different applications.
12" - 73"
CFM
147,000
IN. W.G.
14"

TFB-03
SIZES
Box Type
Tork Box Type Fan is ideal for packages supply, exhaust, air re-circulation and combustion air applications. This fan has a box housing that are flanged on all sides for a more flexible mounting positions.
12" - 73"
CFM
147,000
IN. W.G.
14"

TFB-04
SIZES
Cabinet Type
Tork Cabinet Type Fan is primarily for new retrofit HVAC systems, supply air, return air, exhaust applications to expand system performance within the same space. This fan delivers increased volume at slower speeds at reduced sound levels.
12" - 73"
CFM
147,000
IN. W.G.
14"

TFB-05
SIZES
In-line Type
Tork Inline Type Fan is the perfect air handling equipment where space requirements and sound levels are critical. The straight and in-line flow design eliminates the need for space consuming and it is significantly quieter than any other axial fan alternatives.
12" - 73"
CFM
147,000
IN. W.G.
14"

TFB-06
SIZES
Radial Type
Tork Radial Type Fan is suited for pneumatic conveying, fume and dust control, grinding booth exhaust, forced air drying and cooling, food and drying ovens, sawdust and wood chip conveying, paper trim systems and various high pressure applications.
8" - 28"
CFM
7,200
IN. W.G.
30"

TFB-07
SIZES
PRV Mushroom Type
Tork Power Roof Ventilator (PRV) Mushroom Type Fan is ideal for exhausting hot stale air and helps fresh air to go inside the inlet vents. This fans is suitable for all types of residential, commercial and industrial buildings such as schools, hospitals and warehouses.
12" - 48"
CFM
38,100
IN. W.G.
1 1/4"

TFB-08
SIZES
Wall Fan Direct Driven
Tork Wall Fan - Direct Driven is ideal for supplying fresh air and exhausting hot, stale air in areas such as toilets, locker rooms, electrical rooms, elevator rooms and warehouses. With the motor directly connected to the propeller, it is more compact, space energy efficient.
12" - 36"
MAX CFM
61,400
MAX W.G.
3/8"

TFB-09
SIZES
Wall Fan Belt Driven
Tork Wall Fan - Belt Driven is the same with direct driven fan except that it offers more flexibility in terms of fan RPM speed and CFM. This fan makes it easier to change fan speed and performance through proper pulley combinations and corresponding fan belt.
12" - 60"
CFM
117,800
IN. W.G.
3/8"

TFB-10
SIZES
Mancooler Panel Type
Tork Mancooler Panel Type Fan is designed and constructed to blow high pressure air in any direction. It can be tilted in any position which makes it ideal for spot cooling and general ventilation. It is usually used for factories and steel mills.
12" - 60"
CFM
117,800
IN. W.G.
3/8"

TFB-11
SIZES
Mancooler Tube Type
Tork Mancooler Tube Type Fan is designed and constructed to blow high pressure air in straight and in-line flow direction. Like the panel type fan, it can be tilted in any position which makes it ideal also for spot cooling and general ventilation.
12" - 60"
CFM
84,000
IN. W.G.
3"

TFB-12
SIZES
Tube Axial Type
Known for space efficiency, low pressure ventilation, straight and in-line air flow direction, Tork Tube Axial Type Fan is used extensively in industrial process applications. Uses includes heat, smoke and fume removal, process drying and process cooling and general ventilation.
12" - 60"
CFM
84,000
IN. W.G.
3"

TFB-13
SIZES
Vane Axial Type
Like the Tork Tube Axial Type Fan, Tork Vane Axial Type Fan is known for space efficiency but more moderate pressure and aggressive air streams applications. With the guide vanes, this fan, produces a more accurate straight and in-line air flow direction.
12" - 60"
CFM
88,792
IN. W.G.
4"

TFB-14
SIZES
PRV Cone Type
Tork Power Roof Ventilator (PRV) Cone Type Fan is designed and constructed for exhausting hot stale air. Known for low pressure ventilation, this fan is suitable for residential, commercial, and industrial, buildings such as market place, foundries, factories and warehouses.
12" - 60"
CFM
84,000
IN. W.G.
3"
TORK PROPELLER FANS & BLOWERS
TORK CENTRIFUGAL FANS & BLOWERS
Why use industrial fans & blowers?
​
The Philippines is a tropical rain country thus people living here experience hot and humid weather throughout the year. This type of weather may not be conducive in the work place. Air-conditioning is a solution but may be too expensive for some. With fans and blowers, the dynamics of exhausting hot, polluted air and supplying cooler, fresher air can be achieved at a cheaper cost. Good and proper ventilation creates a safe and comfortable environment for everyone which ensures productivity, effectivity, and efficiency in the work place.
What is Inches of W.G.?
​
​
Inches of W.G. (water gauge) is a British/English form of measurement for static pressure. In a fan, inches of W.G. refers to the resistance to airflow or friction caused by moving air through a pipe, duct, hose, filter, hood slots, air control dampers or louvers. A Pitot Tube or Airflow Meter Kit is used to measure the fan's actual inches of W.G. Like measuring CFM, measuring inches of W.G. is taken when the fan is on its highest speed. The fan is connected to a round duct with a damper at the end of it, and a pitot tube inserted through a small hole in the duct connected to a U-tube water gauge determining the static pressure.
What is CFM?
​
​
​
CFM stands for cubic feet per minute. It is a British/English form of measurement for volume flow. In a fan, CFM refers to as airflow or how much air a fan moves. A testing instrument called Velometer/Anemometer or Airflow Meter Kit is used to measure the fan's actual CFM. The measurement is taken when the fan is on its highest speed and uses both the volume of air and the rate at which it moves. The CFM depends on the following parameters: type of fan, size of fan and wheel diameter, the blade pitch, the fan's motor. The greater the CFM, the more air a fan will move.
Why choose TORK industrial fans & blowers?
​
With three (3) decades of experience in the industry of designing and manufacturing industrial fans and blowers, TORK Philippines, Inc. (TPI) is market proven and one of the best in the country. TPI offers a wide variety of ventilation products which are tailored suit for different applications and customer needs. Being a company that is customer driven, TPI also offers preventive maintenance, corrective repairs and overhauls of industrial fans and blowers supplied to customers so as to maintain the fan's high efficiency and good running condition.













How to select a fan?
​
​
In selecting a fan, the following data are required:
​
1.
Fan Application
Will the fan be used for kitchen exhaust, for supply fresh air or for what other applications?
2.
Air Flow Rate
Usually in CFM
(cubic feet per minute)
​
3.
Static Pressure
Usually in inches of W.G.
(water gauge)
​
4.
Motor Phase
Either in three (3) phase or single (1) phase
​